beautypg.com

Desa CD32M (-1)(-2) User Manual

Page 15

background image

- 14 -

For more information, visit www.desatech.com

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

• Pilot will not stay lit after

carefully following lighting
instructions.









• Pilot lit but no flame on the

burner.






































• Frequent pilot outage problem.


• Defective pilot generator

(thermocouple).










• Remote or wires defective.









• Thermopile/Thermocouple not

generating sufficient millivoltage.








• Plugged burner orifice.




• Thermocouple not generating

sufficient millivoltage.















• Pilot flame maybe too low or

blowing (high) causing the valve
safety to drop out.

• Check pilot flame. It must

impinge on thermocouple.

• Clean or adjust pilot for

maximum flame impingement on
thermocouple.

• Ensure that the connection

between the valve and
thermocouple are tight and
secured.



• Check remote wires for proper

connections. Jumper wire across
terminals at remote control, if
burner comes on, replace
defective remote. If okay, jumper
wire across remote control at
valve, if burner comes on, wires
are faulty or connections are bad.



• Check thermopile with millivolt

meter. Take reading at
thermopile terminals of gas valve.
Should read 325 millivolts
minimum with remote control off.
Replace thermopile if reading is
below specified minimum.


• Check burner orifice for stoppage

and remove.




• Check thermocouple with

millivolt meter. Take reading at
thermocouple terminals of gas
valve. Should read 18 millivolts
minimum with remote control off.
Replace faulty thermocouple if
reading is below specified
minimum.









• Clean and/or adjust pilot flame

for maximum flame impingement
on thermocouple.




This manual is related to the following products: