CARE AND MAINTENANCE

SEE THE CARE & MAINTENANCE INSTRUCTIONS FOR DETAILS ON THESE PROCEDURES.

Weekly Maintenance:

There are several areas and parts of the unit that must be inspected and cleaned at least once a week during
operation. However, depending on fuel quality and burning habits, this maintenance may have to be performed more
frequently. These are:

A.

Heat exchanger tubes.

B.

Ceramic log set. (Optional)

C.

Brick refractory.

D.

Firepot and holder.

E.

Ashpan.

F.

Glass and door maintenance.

1000 Pounds (1/2 ton) of Fuel Used Maintenance:

There are several areas and parts of the unit that should be inspected and cleaned after every 1000 pounds (1/2 ton)
of fuel used. These are:

Repeat items A through F.

G. Exhaust ducts.

H. Hopper and auger tube area.

6000 Pounds (3 tons) of Fuel Used Maintenance:

The 6000 pounds (3 tons) of fuel used maintenance requires disassembly of the unit and its components. We
recommend this procedure be carried out by a trained service person or your dealer. The following areas should be
inspected, cleaned and serviced after every 6000 pounds (3 tons) of fuel used.

Repeat Items A through H.

I.

Exhaust fan (including exhaust duct system).

J.

Convection fan.

K.

Chimney system.