FREESTANDING RESIDENTIAL INSTALLATION (Cont.)
Alcove Installation
If you are installing your appliance into an alcove, you must follow all of the directions for the type of
installation (e.g. standard ceiling installation, cathedral ceiling installation, etc.) you are using and follow
the additional specifications listed below.
Minimum Alcove Dimensions
G
H
J
996 Flush Top Flue
Shown Here Ð Follow the
clearances for the 996
Extended 45 Flue when
that model is used.
Backwall
Sidewall
A
B
E
D
Sidewall
D
A
Combustible Alcove
996 Flush
Top Flue
996
Extended
45o Flue
Non-Combustible
Alcove*
996 Flush
Top Flue
996
Extended
45o Flue
A. Sidewall to unit..............
14"
16"
A. Sidewall to unit..............
6"
6"
B. Backwall to unit .............
9 1/2"
14"
B. Backwall to unit .............
2"
4"
D. Connector to sidewall ..
23"
25"
D. Connector to sidewall ..
15"
15"
E. Connector to backwall . 10"
10"
E. Connector
to
backwall................................
2 1/2"
2"
G. Max. Depth of Alcove ...
48"
48"
G. Max. Depth of Alcove ...
48"
48"
H. Min. Width of Alcove.....
53 1/2" 57 1/2" H. Min. Width of Alcove.....
37 1/2"
37 1/2"
J. Min. Height of Alcove ...
84"
84"
J. Min. Height of Alcove ...
**
**
*
Non-Combustible Alcoves include alcoves made of brick, stone, or concrete with at least 3 1/2" of
thickness along the walls and ceiling that is also spaced and ventilated at least 1" off of the
combustible wall to allow air to move around the non-combustible walls and ceiling.
**
6" Above Stove Top