beautypg.com

Installation, Mantel requirements – Avalon Firestyles Hideaway User Manual

Page 26

background image

2 6

Installation

(for qualified installers only)

Travis Industries

4030612

1 0 0 - 0 1 1 4 8

Mantel Requirements

The combustible area above the facing must not protrude more than 3/4" from the facing. If it does, it
is considered a mantel and must meet the mantel requirements listed below.

Use the table below to determine the maximum mantel depth allowed. For example, if a 6” mantel is
used, it must be a minimum of 6-1/2” above the face.

Maximum Mantel Depth (b)

Mantel

Height

Above

Face (a)

0”

1”

2”

8”

7”

6”

5”

4”

3”

9”

35-1/2”

a

b

If you have a tapered mantel, measure the
mantel height at the point where it
protrudes 3/4” in front of the face.

0” 1” 2” 3” 4” 5” 6” 7” 8” 9” 10” 11” 12”