Power consumption testing, Table 6, 6 power consumption testing – Dell POWEREDGE R610 User Manual
Page 23
Dell
PowerEdge R610 Technical Guide
23
Maximum Shock
Storage
Half sine shock on all six sides of 71G 5% with a
pulse duration of 2ms 10% Square wave shock on
all six sides of 27G with velocity change @ 235
in/sec or greater
Altitude
Operating
-16 to 3048m (-50 to 10,000ft) Note: For
altitudes above 2950 feet, the maximum
operating temperature is de-rated 1°F/550ft
Storage
-16 to 10,600m (-50 to 35,000ft)
5.6 Power Consumption Testing
Table 6.
Power Consumption Testing
Feature
Energy Smart Power Supply High Output Power Supply
Dimensions
L-249 mm
1
x W-65.5 mm x H-38.2 mm
Status Indicators
1 x bi-color Light Emitting Diode
Integrated Fans
None
Fixed Input Plug
IEC-C14
AC Cord Rating
15 Amps @ 120 VAC, 10 Amps @ 240 VAC
Input Voltage
90–264 VAC
Auto-ranging
Yes
Line Frequency
47–63 Hertz
Maximum Inrush Current
55 Amps per supply for 10 ms or less
Hot-Swap Capability
Yes
Output Power
502 Watts
717 Watts
Maximum Heat Dissipation 1712.9 BTU per hour
2446.5 BTU per hour
Efficiency (20% – 100%
Load)
86.5–90% @ 115 VAC
88–92% @ 230 VAC
85–88.5% @ 115 VAC
86.5–90.5% @ 230 VAC
1
Does not include the power supply handle or ejection tab