Installation, Optional wall switch or thermostat installation, For qualified installers only) – Avalon Firestyles 864 See-Thru GS2 Installation User Manual
Page 21: Parallel connection series connection

Installation
(for qualified installers only)
21
© Travis Industries
4141208
100-01404
Optional Wall Switch or Thermostat Installation
Do not connect 110-120 VAC to the gas control valve or wiring system of this fireplace. The switch and
wiring must be installed by a qualified installer.
This fireplace includes an optional wall switch (with wire) to
operate the fireplace burner without accessing the internal
on/off switch. A thermostat may be used instead.
Route the wire from inside the fireplace, through the grommet
on either side of the fireplace near the gas inlet (see at right)
to the switch. The wall switch (or thermostat) may bypass the
fireplace on/off switch or be installed in parallel or series
configuration (see below).
Caution:
Label all wires prior to disconnection when
servicing controls. Wiring errors can cause
improper and dangerous operation.
Note:
When using a GreenSmart™ remote, use the
receiver for on/off operation (do not use a wall
switch or thermostat).
Warning: Make sure all wiring is secure and does not
contact hot or moving components.
Parallel Connection
Series Connection
On / Off Switch
ON
On / Off Switch
OFF
On / Off Switch
ON
On / Off Switch
OFF
Thermostat / External
Switch ON
Heater is ON
Heater is ON
Thermostat /
External Switch ON
Heater is ON
Heater is OFF
Thermostat / External
Switch OFF
Heater is ON
Heater is OFF
Thermostat /
External Switch OFF
Heater is OFF
Heater is OFF
To wire the heater in parallel, follow the directions below:
To wire the heater in series, follow the directions below:
OPTIONAL WALL SWITCH
(included with fireplace)
Place "WARNING"
label on switch cover.
Thermostat
(or External Switch) Wires
a
b
c
On / Off Switch
a
On / Off Switch
c
b
Thermostat
(or External Switch) Wires