2 monitoring device critical errors, 6 oosd tests, Commands execution – Artesyn ViewCheck on ATCA-7470/7475 Installation and Use (May 2014) User Manual
Page 86

Commands Execution
ViewCheck on ATCA-7470/7475 Installation and Use (6806800S49C)
86
5.5.2
Monitoring Device Critical Errors
Under Linux OS, the Device Drivers LOG abnormal behavior and potential errors occurring in
the Hardware device with KERN_ERR or KERN_CRIT category. These notifications are
considered as potential errors as they could manifest into latent faults in the live system.
As part of monitoring the Device Critical errors, all such Kernel CRITICAL and Kernel ERROR
notifications have been extracted from the PNE Kernel () driver sources and represented in the
form of a database.
The In Service Monitoring Module of ViewCheck would watch out for the occurrence of these
notifications and on detection would send a notification to XML.
The Device Errors are captured and are identified uniquely by ERROR ID. For definition of
ERROR ID, refer
.
5.6
OOSD Tests
OOSD Tests are used to monitor and manage the performance of the hardware components of
blades. You can execute these tests only when blades are offline, that is blades are not
providing any service.
HDD Health Status
1010
sda1 to sda8
sdb1 to sdb8
Monitors the Health Status of the
sda1 to sda8 partitions on the
HDD and reports.
Network Errors
1020
base1(70), base2(71),
fabric 1(73), fabric 2(74),
rtm1(147),
Monitors the various Error
counters for each of the Network
Device Instances and provides an
error counter exceeds the rate of
change.
Network Counters
1021
base1(70), base2(71),
fabric 1(73), fabric 2(74),
rtm1(147),
Monitors the various counters for
each of the Network Device
Instances
Table 5-28 Monitors (continued)
Monitor Description
Monitor
ID
Valid Device Instances
Remarks
- ViewCheck on ATCA-7470/7475 Installation and Use (September 2014) ViewCheck on ATCA-7370 Installation and Use (November 2014) ViewCheck on PrAMC-7311 Installation and Use (November 2014) ViewCheck on ATCA-F140 Installation and Use (September 2014) ViewCheck on ATCA-7470/7475 Installation and Use (November 2014) ViewCheck on PrAMC-7311 Installation and Use (September 2014) ViewCheck on ATCA-9405 Installation and Use (May 2014) ViewCheck on ATCA-F140 Installation and Use (November 2014) ViewCheck on ATCA-9405 Installation and Use (September 2014) ViewCheck on ATCA-7480 Installation and Use (April 2015) ViewCheck on ATCA-9405 Installation and Use (November 2014) ViewCheck on PrAMC-7311 Installation and Use (May 2014) ViewCheck on ATCA-7370 Installation and Use (April 2014) ViewCheck on ATCA-F140 Installation and Use (April 2014)