beautypg.com

Interface connector, Interface pinout – AMETEK LPDC-65V User Manual

Page 2

background image

Technical Note

ReFlex Power™ Mating Connectors for LPDC-65V Module

Document No. W380270-02 Rev E •

1/23/2009

©2008 AMETEK Programmable Power, Inc. • All rights reserved. • AMETEK is a trademark of AMETEK, Inc.

9250 Brown Deer Road, San Diego CA 92121 • Tel: 858-450-0085 • Fax: 858-458-0267 • email:

[email protected]

• Web:

www.programmablepower.com

2 of 4

INTERFACE CONNECTOR

External isolated digital and analog control interface.
Connector: Positronic Industries P/N SD9M1000Z, AMETEK P/N 856-214-09

Crimp contacts: Positronic Industries P/N MC7520D (initially supplied with connector)

Backshell: Positronic Industries P/N D9000Z00, AMETEK P/N 856-247-10
Wire size: Maximum gauge 20 AWG (recommended)

Maximum length 10 meters (can be extended subject to environment, cable type, and interface circuits).

INTERFACE PINOUT

Figure 2. Interface Connector, Front Panel View, and Interface Connector Wiring Diagram

Pin

Name Function

Signal

Level

Wire Gauge,

AWG

1 ENA

1

Input: module output enable

TTL logic level

20

6 ENA-RTN

1

Input: return for ENA signal; connected to Pin-7/8

Signal common

20

2

TRIG-OUT

Output: trigger output signal

TTL logic level

20

7

TRIG-OUT-RTN

Output: return for TRIG-OUT; connected to Pin-6/8

Signal common

20

3

TRIG-IN

Input: trigger input signal

TTL logic level

20

8

TRIG-IN-RTN

Input: return for TRIG-IN; connected to Pin-6/7

Signal common

20

4 Reserved

9 Reserved

5 CHAS-GND

Shield

ground

Chassis

ground

20

1

Enable signal is internally pulled up to +5 V with a 10 K resistor. To enable the module, the signal is pulled low (<= 0.5 V) with respect

to the ENA RTN signal; this may also be accomplished by shorting Pin 1 to Pin 6.

This manual is related to the following products: