INTEGRATION CHECKS
Once you have correctly completed a standard integration, you should be able to answer ‘Yes’ to the
following questions:
9
Is the gasket used between the LCD and the touch sensor of the correct thickness?
9
Is the sensor fitted with the glass face forward (Viewing Face Label visible)?
9
Is the controller grounded either through the mounting standoffs or via a low impedance
ground cable?
9
Is the controller spaced away from the metal chassis by at least 5mm?
9
Are the flexible cables routed so that they do not cross over each other?
9
Are the flexible cables bent to radius of no less than 2.5mm where they attach to the glass?
9
Are the flexible cables inserted into the correct ZIF connector sockets?
9
Are the flexible cables inserted into the ZIF connector sockets with the gold contacts visible?
9
Are the flexible cables fully inserted into the ZIF connector sockets?
9
Are the flexible cables locked into the ZIF connector sockets?
9
Is the USB cable plugged directly into a USB port on the PC?
9
If a metal bezel has been used, is it spaced away from the front face of the sensor with the correct
gasket thickness of 3mm?
9
If a metal bezel has been used, is it grounded to a common ground point with the metal chassis,
LCD and controller PCB?