beautypg.com

Thor 2 mW CATV RF Over Fiber Tx 45-870 MHz User Manual

Page 11

background image

11

3. Close the units cover to insure

good shield. If possible, set shielded

cover at optical connector and

earthing the shielded cover

After connecting to the

network, the optical

channel has obvious noise

problems.

C/N ratio index of some channels too

low

Check C/N ratio of the channel signal

and do some proper adjustment.

After connecting the

equipment, the signal has

obvious noise problems

Interference of power alternating

current wave caused by bad

equipment earthing or power supply

problems.

Check the equipment’s earthing,

insure every unit on the rack has good

earthing with resistance <4Ω.

After connecting

equipment, received

optical power at optical

connector is abnormal.

Output RF signal is also

not standard, but output

optical power is normal

1. Optical fiber active connector

wrong matched. Maybe APC

connector match PC connector,

under these conditions there

are optical reflections.

Optical active connector or adapters

were badly polluted, or adapter was

damaged.

1. Check type of optical fiber active

connector, choose APC connector to

insure optical signal transmits

normally.

2. Wash polluted optical active

connector or adapter. Detailed

operation method refers to optical

fiber active connector clean and

maintenance method.

9.

Service

a)

Our company's promises: Guarantee for thirteen month (start from the production

date showed on S/N ),

we will fix any equipment problems. If the fault is found to

be caused by user error, there may be a charge for these repairs.

b) If the equipment at fault, immediately contact local distributor or our company

customer service centre.

c)

Equipment at fault that is repaired locally must be fixed by a special technician to

avoid further damage.

d) Special caution: if the user has altered the equipment, our company will not offer

free repair. We will repair the equipment, but the end user is responsible for cost.

The clean and maintenance method of the head of fiber active connector

During the operation of optical equipment, each active fiber may be polluted by dust or dirt,

resulting in optical link path loss. If optical receive power and output level of the receiver decline,

you should clean and maintain active fiber connector. Introduce some clean methods:

Carefully screw off the active fiber connector from the adapter. Take care to avoid

aiming at the human body or eye, this can result in harm to the body.