Suitable for monitoring of emergency-stop circuits
Yes
Suitable for monitoring of optoelectronic protection equipment
Yes
Suitable for monitoring of position switches
Yes
Output circuit
Enabling paths
3
Signaling paths
1
Contact material
Ag-alloy, gold-plated
Max. thermal current Ith, enabling paths
6 A
Max. thermal current Ith, signaling paths
2 A
Max. total current I2 of all current path
25 A²
Application category AC-15 (NO)
Ue 230V, Ie 3A
Application category DC-13 (NO)
Ue 24V, Ie 5A
Short-circuit protection (NO), max. fuse insert
6 A class gG fuse, fuse integral < 100 A²s
Mechanical life
107 switching cycles
Control circuit
Nominal output voltage DC
22.5 V
Input current (safety circuit / reset circuit)
25 mA
max. peak current (safety circuit / reset circuit)
100 mA
Response time tA1
250 ms
Response time tA2
250 ms
Min. switch-on time
60 ms
Recovery time tW
120 ms
Release time tR
20 ms
Synchronous time tS
1.5 s
Permissable test pulse time tTP
0.8 ms
max. resistivity, per channel
≤ (5 + (1,176 x UB / UN - 1) x 100) Ω
Type of switch function of the inputs
Normally open contact
Evaluation inputs
2-channel
Supply circuit
Nominal voltage UN
DC 24 V
Rated consumption DC
1.6 W
Operating voltage min.
22.4 V
Operating voltage max.
26.4 V
Dimensions
Depth
114 mm
Width
22.5 mm
Height
96.5 mm