Overview – Pinnacle Systems SLT Series User Manual
Page 10

2
Overview
SLT Series
Specif
Specif
Specif
Specif
Specifica
ica
ica
ica
ications
tions
tions
tions
tions
Emitter and Receiver Pylons
Input Power:
120VAC +/- 10% VAC @ 50-60 Hz, 12 watts max/pylon
24VDC(optional)
Safety Relays
Two force-guided self-checking N.O. relays in series rated at
4 AMPS @ 120VAC
Isolated (DRY) Normally Open contacts. --||--||--
130VAC maximum
Auxiliary Relay
N.O. or N.C.
Output Circuit:
Solid State Output
Two PNP outputs rated at 500mA each. The solid state outputs must
never be placed in series or parallel and are not to be used as the final
switching element(s).
Fuses:
Power: Surface mount replaceable 1A Slow Blow
External Indicators:
Receiver Pylon
1) GREEN = Output Relay contacts closed (OK)
2) RED = Output Relay contacts open (NOT OK)
3) Diagnostics Display (single digit alphanumeric)
Emitter Pylon
RED = Sync channel alignment indicator
(11-1/2” down, viewable only from inside unit)
Construction
Aluminum extrusion with steel end caps, mounting brackets, and replaceable
polycargonate lens. NEMA 4 (without blanking keyswitch).
Temperature Range:
32º to 120º F
Dimensions:
See Dimensional Information
Beam Spacing:
3/4" (19mm)
Minimum Sensitivity
Without Blanking:
1-1/4" (32mm)
Response Time:
< 30 milliseconds (all lengths)
Scanning Frequency:
3.6 Khz