beautypg.com

NEXCOM VMD 3002 User Manual

Page 30

background image

Copyright © 2013 NEXCOM International Co., Ltd. All Rights Reserved.

VMD 3002 User Manual

22

Chapter 6: Table for MCU Protocol

Command 0x37: Return Reboot

Command 0x41: Return Update Mode

Command 0x31: Return BSL Info

Direction: MCU -> Host
The MCU sends this command in response to the command “Command
0x32: SendReboote” sent by the Host.

Direction: MCU -> Host
The MCU sends this command in response to the command “Command
0x41: ReadUpdateMode” sent by the Host.

Direction: MCU -> Host
The MCU sends this command in response to the command “Command
0x30: ReadBSLInfo” sent by the Host.

Data Structure

Length

Comment

State

1

0x01: Reboot (Wait for 3 sec)
0x00: Non

Data Structure

Length

Comment

State

1

0x01: Update mode
0x00: Normal mode

Data Structure

Length

Comment

Product_Name

16

The Product Name will be read

MCU TYPE

16

The Device Family Type will be read

Flash Lock Password

8

The Flash Lock Password will be read

Boot Loader Version

8

The Boot loader version will be read

Application Version

8

The Application version will be read

Command 0x40: ReadUpdateMode

Command 0x42: IsRequestUpdate

Command 0x36: IsRequestReboot

Direction: Host -> MCU
The Command has no extra data.

Direction: Host -> MCU
The Command has no extra data.

Direction: Host -> MCU
The Command has no extra data.

Command 0x43: Return Request Update
Direction: MCU -> Host
The MCU sends this command in response to the command “Command
0x42: IsRequestUpdate” sent by the Host.

Data Structure

Length

Comment

Data

4

Fixed Data as below:
0x55 0xCC 0x00 0xFF

Command 0x7F: Return Invalid Command
Direction: Host -> MCU
The Command has no extra data.