beautypg.com

Specifications – NEXCOM VMD 3002 User Manual

Page 10

background image

Copyright © 2013 NEXCOM International Co., Ltd. All Rights Reserved.

VMD 3002 User Manual

2

Chapter 1: Product Introduction

Specifications

General

Enclosure: Plastic PC + ABS

Mounting: Support VESA 75/100

Power Input: 9~36VDC

Power Consumption: 18W

Ingress Protection: IP65

Dimension: 256.5 x 202.1 x 31.5 mm

Weight: 1.64Kg, 4.16Lb

LCD Panel

10.4-inch TFT LCD panel with LED backlight

1024 x 768 pixels (XGA)

Brightness: 1200 cd/m² (typical, after touch screen is 1080cd/m

2

)

Contrast Ratio: 500:1 (typical)

Touch Screen Sensor

Projected capacitive touchscreen

Surface Hardness: 6H

Multiple touch

I/O Interface-Front

1x LED indicators (Power on/off, Auto Back-light, MCU update)

IR remote sensor

I/O Interface-Lateral

On screen display buttons x 7

Display power on/off

OSD Menu

Volume control (+/-)

Brightness control (+/-)

Auto Configuration

I/O Interface-Bottom

Pigtail with multiple IO interface

4x CVBS connector

1x Line-in

1x VGA

1x USB

1x COM (TX/RX)

1x Power input connector (9 ~ 36Vdc)

Environment

Operating temperature: -30°C to 60°C

Storage temperature: -30°C to 80°C

Vibration (random): 2.5g@5~500 Hz

Vibration

Operating: MIL-STD-810G, 514.6 Procedure 1, Category 4, Ground

Vehicle – Highway Truck

Storage: MIL-STD-810G, 514.6 Procedure 1, Category 4, Integrity Test

Shock

Operating: MIL-STD-810G, Method 516.6, Procedure I, Trucks and

semi-trailers= 20g

Crash hazard: MIL-STD-810G, Method 516.6, Procedure V, Ground

equipment= 75g

Standards/ Certifications

CE approval

FCC Class B