Low voltage protection settings – NEXCOM VES30-4S User Manual
Page 22
Copyright © 2014 NEXCOM International Co., Ltd. All Rights Reserved.
11
Chapter 3: Description of the External Connector Pinouts
VES30-4S and VES30-8S User Manual
Low Voltage Protection Settings
Low Voltage Protection
12V System
24V System
Minimum power on voltage
Minimum operation voltage
Minimum power on voltage
Minimum operation voltage
Pin 6
Pin 5
Disabled (9~36V)(*)
Disabled (9~36V)(*)
Disabled (9~36V)(*)
Disabled (9~36V)(*)
0
0
11.5V
10.5V
23V
21V
0
1
12V
11V
24V
22V
1
0
12.5V
11V
25V
22V
1
1
* If the vehicle battery voltage drops lower than the above minimum power on and minimum operation voltages for 6 minutes, VES30 will be shut down.
** If the vehicle battery voltage ranges between 6V~9V for 30 seconds, VES30 will be shut down.
(*) Default setting
1
ON
2
3
4
5
6
7
8
Pin 1
OFF (Default)
Pin 8