beautypg.com

Appendix a: power consumption, Power consumption management – NEXCOM NISE 4000 User Manual

Page 99

background image

Copyright © 2013 NEXCOM International Co., Ltd. All Rights Reserved.

84

NISE 4000 User Manual

Appendix A: Power Consumption

Appendix A: Power Consumption

Power Consumption Management

Purpose

The purpose of the power consumption test is to verify the power dissipation
of system, and the loading of power supply.

Test Equipment/Software

▪ 19” LCD Monitor.

▪ DC power supply.

▪ CM-07 AC/DC CLAMP METER.

▪ Operating System OS: Windows 7 (64 bit)

▪ Burn In Test Ver 7.1

▪ Kpower Software.

▪ Network test program.

Device Under Test

DUT: SYS#1 (S/N: TBBD05028771)

Test Procedure

1. Make sure mechanical structure and electrical functionality are normal

before testing.

2. Install all I/O load devices and according as system input voltage

specifications to setup DC Power supply voltage.

3. Measure system maximum power consumption as below mode:

▪ Standby mode.

▪ BIOS mode.

▪ 100% Full loading mode.

4. Measure and record system maximum power consumption value.

Test Result

System Mode

System No.: TBBD05028771

+24Vdc

Imax.

Wmax

Intel

®

Core™ i5-3610ME

CPU 2.7 GHz/35W

BIOS version: R1.0a
(N400-008)

Standby mode. (S3)

0.16 A

3.84 W

BIOS mode

1.06 A

25.44 W

100% Full loading mode.

2.13 A

51.12 W