beautypg.com

3 troubleshooting, 1 self-testing – KBC Networks ESUG8P User Manual

Page 10

background image

Ethernet Switch User Manual

Manual-ESUG8P_Series_HW-Rev1112
Copyright © KBC Networks Ltd.

Page 10 of 14

www.kbcnetworks.com

3 Troubleshooting

3.1 Self-testing

When the device is powered on, the top green LED on the RJ45 ports will flash once

then go out, the bottom green LED on the RJ45 will light in succession, starting at P1

to P8, each port will continue to light in turn unless it is connected to an external

device. The power (P1 & P2) and P-Fail LEDs will be lit according to the power being

supplied to the unit and the DIP switch selection (see Section 2.7).

If problems are encountered when using this Ethernet switch please check the

following:

Verify that the correct power supply unit is being used; this unit requires a

48Vdc supply.

Ensure that the correct cables are being used to construct your network:

o Unshielded Twisted Pair or Shielded Twisted Pair for RJ45 connections

o 100Ω Cat 3 cable or above for 10Mbps connections

o 100Ω Cat 5 cable or above for 100Mbps connections

o 100Ω Cat 5e cable or above for 1000Mbps connections

o Twisted pair connection must not exceed 100m (328 feet)

See section 2.7 for LED status indicators.