C8000

4 Channel unbalanced AES/EBU I/O

C8189

Jünger Audio Studiotechnik GmbH
Justus-von-Liebig-Strasse 7
D -12489 Berlin
Germany

phone: +49-30-677721-0
fax:

+49-30-677721-46

[email protected]
www.junger-audio.com

4/10

rotary encoder settings

ADDRESS

0 – F

sets the CAN ID . The 16 switch positions are hexadecimal numbers (0x0
to 0xF). Each module within a frame must be assigned a unique CAN
bus address for proper communication with other modules of the frame.

Important note! To avoid audio bus conflicts when you replace a module or install an additional one and
the configuration is unknown, the output bus drivers must be disabled by BUS-EN=OFF before inserting it.
If all settings are done remotely and the unit fits into the bus assignment scheme of a frame, you must
remove it and place the switch back into position BUS-EN=ON.

INIT

the button initializes the module to factory default if one holds it down
while power up.