C8189, C8000, Digital audio modular processing system – Junger Audio C8189 - AES/EBU I/O on BNC User Manual
Page 4: 4 channel unbalanced aes/ebu i/o
digital audio
modular
processing system
C8000
4 Channel unbalanced AES/EBU I/O
C8189
Jünger Audio Studiotechnik GmbH
Justus-von-Liebig-Strasse 7
D -12489 Berlin
Germany
phone: +49-30-677721-0
fax:
+49-30-677721-46
[email protected]
www.junger-audio.com
4/10
rotary encoder settings
ADDRESS
0 – F
sets the CAN ID . The 16 switch positions are hexadecimal numbers (0x0
to 0xF). Each module within a frame must be assigned a unique CAN
bus address for proper communication with other modules of the frame.
Important note! To avoid audio bus conflicts when you replace a module or install an additional one and
the configuration is unknown, the output bus drivers must be disabled by BUS-EN=OFF before inserting it.
If all settings are done remotely and the unit fits into the bus assignment scheme of a frame, you must
remove it and place the switch back into position BUS-EN=ON.
INIT
the button initializes the module to factory default if one holds it down
while power up.