Ac power, Power consumption, Ac plug – ILUMINARC Ilumipod™ 36g2 IP User Manual
Page 11: Power wiring, Installation
Installation
Ilumipod™ 36g2 IP User Manual Rev. 2
7
Always connect
the Ilumipod™
36g2 IP to a
protected circuit with an
appropriate electrical
ground to avoid the risk of
electrocution or fire.
Never connect
the Ilumipod™
36g2 IP to a
rheostat (variable resistor)
or dimmer circuit, even if
the rheostat or dimmer
channel serves only as a
0–100% switch.
Make sure to
connect the
Ilumipod™ 36g2
IPto a power line with the
proper voltage and
frequency, as per the
specifications in this
manual or on the product’s
sticker.
AC Power
The Ilumipod™ 36g2 IP has an auto-ranging power supply that works with an input voltage
range of 100–277 VAC, 50/60 Hz.
Make sure that you are connecting this product to the proper voltage, as per the specifications
in this User Manual or on the product’s sticker.
Power Consumption
To determine the power requirements for the Ilumipod™ 36g2 IP, refer to the label affixed to
the side of the product. Alternatively, you may refer to the
The listed current rating indicates the maximum current draw during normal operation.
AC Plug
The Ilumipod™ 36g2 IP comes with a bare-ended power input cord for hardwire installation.
Use the table and the illustration below to wire a plug.
Connection
Wire (U.S.)
Screw Color (U.S.) Wire (Europe) IP67 Pin
AC Live
Black
Yellow or Brass
Brown
1
AC Neutral
White
Silver or Gray
Blue
2
AC Ground
Green/Yellow
Green
Green/Yellow
3
Power Wiring
You can connect the bare-ended, IP67-rated AC power cable from the product to an IP67-rated
power connector or IP67-rated junction box.
If using junction boxes, make sure to use IP67-rated conduit for surface installations.
The listed current
rating indicates
the maximum
current draw
during normal operation.
If you choose to
bury the power or
signal distribution
boxes, make sure that
they are IP67-rated or
greater.