Future automation, Contact closure, La - lifting arm – Future Automation LA User Manual
Page 7: Control details

Sheet 7 of 8
ISSUE: 001
www.futureautomation.co.uk
FUTUREAUTOMATION
LA - Lifting Arm
Control Details
PIN
568
A
568
B
DESCRIPTION
ACTION
1
2
3
4
5
6
7
8
W/G
G
W/O
BL
W/BL
O
W/BR
BR
W/O
O
W/G
BL
W/BL
G
W/BR
BR
12V SUPPLY CURRENT LIMITED
12V TRIGGER
GROUND
DEVICE STOP
DEVICE IN
DEVICE OUT
When 12V is attached, will go OUT.
When 12V is removed, will go in.
Momentary short to ground to
toggle from in to out and out to in. CC5
Short to ground will make device go out.
Release short to go in. CC4
Momentary short to ground,
stops device in current position. CC3
Momentary short to ground
will make device go in. CC2
Momentary short to ground
will make device go out. CC1
Contact Closure
Use an RJ45 connector in the
CC1 socket on the control box
to operate via contact closure.
DEVICE LATCH
DEVICE TOGGLE