Lsl pf - lift system light push flap – Future Automation LSL-PF User Manual
Page 15
![background image](https://www.manualsdir.com/files/769136/content/doc015.png)
In
st
all
at
io
n
: R
S
23
2 C
on
tro
l
Page 14 of 18 // email [email protected] tel: +44 (0) 1438 833577 fax: +44 (0) 1438 833565
LSL PF - Lift System Light Push Flap
Connection Locations
Mains Voltage Input
IR LED
IR Input Jack
RS232
Contact Closure
SLQV
RS232
- Use an RJ25 connector
in the socket marked
RS232 on the control box
to operate using RS232
Details
Baud rate: 9600
Stop bit:
1
Parity:
None
Databits:
8
Pin 1: RX
Pin 6 : TX
Pin 3 & 4: GROUND
Pin 2: TX
Pin 3: RX
Pin 5: GROUND
IMPORTANT
Ensure protocol is entered exactly
as written, including Carriage Return
(Enter / ASCII 13).
RJ25
9 PIN D
PIN 1: RX
TO
PIN 2: TX
PIN 6: TX
TO
PIN 3: RX
PIN 3: GROUND
TO
PIN 5: GROUND
PIN 4: GROUND
TO
PIN 5: GROUND
Protocol
Action
fa_in Carriage Return (Enter )
Device IN
fa_out Carriage Return (Enter )
Device OUT
fa_stop Carriage Return (Enter )
Device STOP (At any position)
Emergency Stop Connector