Captiview configuration – Doremi CaptiView User Manual
Page 12

D2K.DP.000469.DRM
Page 12 of 27
Version 2.1
Doremi Labs
Figure 7: List of Devices - Closed Caption Example
Click the Add button (Figure 7).
The user will now be back to the Device Manager GUI to finish configuring the device.
2.2.2 CaptiView Configuration
To finish configuring the device, complete the fields in the Closed Caption Configuration window
(Figure 8).
Check the Enabled box to enable this feature.
It is recommended to leave the default settings as they are, except for the Auditorium
field.
In the Auditorium field, choose any channel other than 0. For example, choose 1, 2, 3,
etc., but do not leave the channel set at 0. The number, once saved, will be saved to the
USB transmitter which then must be power-cycled by unplugging and then re-plugging
the transmitter. This applies to software versions 2.0.10 and higher.
Note: To change the current auditorium number while using software versions 2.07 or below,
contact Doremi Technical Support to receive a hot fix. In software version 2.0.10 and higher, the
user can change the auditorium setting from the Device Manager GUI.
Define the Play Offset, Idle Text, and Idle Time.
o Play Offset: This feature offsets the Closed Captioning data in the form of
milliseconds.
o Idle Text: The default text that is shown on the display.
o Idle Time: The time it takes for default Idle Text to appear after loss of input.
Click the Save button.