Mounting options and angle settings, Assembly, Mounting options and angle settings 1.5. assembly – d&b Z5389 Bi6-SUB Horizontal bracket User Manual
Page 5
1.4. Mounting options and angle settings
Mounting holes are provided on the tie bar of the bracket.
One 9 mm (0.35") hole is provided at each end of the tie bar for
fixing the bracket directly to the ceiling.
Two 9 mm (0.35") holes at the d&b standard spacing of 115 mm
(4.5") are provided to allow the attachment of the Z5010 TV
spigot.
Each end of the bracket is equipped with a semi-circular slot to
allow the subwoofer to be vertically aligned within a range of 45°
(+30°/—15°) as standard. Depending on the onsite conditions
—30° may also be possible.
1.5. Assembly
Attaching the bracket to walls or ceilings
NOTICE!
Only use mounting parts (fixing anchors and screws) that are
suitable for the intended application.
Observe the occurring extraction forces acting on the fixing
anchors and screws. The rated extraction forces for the respective
application (wall or ceiling mounting) and cabinet are listed in the
following table.
Application
Rated extraction forces
Ceiling mounting
400 N
To attach the bracket to the ceiling, use the holes shown in the
graphic opposite to provide adequate support.
A corresponding fixing template is supplied with these mounting
instructions. Refer to Þ Chapter 2. "Fixing template"
Z5389 Mounting holes
d&b Z5389 Mounting instructions 1.1 en
5