beautypg.com

Battery, Maintenance – Dixon Kodiak SE 5225 KOH CE User Manual

Page 36

background image

Battery

your mower is equipped with a maintenance free
battery and does not need servicing. However,
periodic charging of the battery with an automotive
type battery charger will extend its life.

Keep battery and terminals clean.

Keep battery bolts tight.

Recharge at 6-10 amperes for 1 hour

IMPORTANT INFORMATION

Do not attempt to open or remove caps or
covers. Adding or checking level of electrolyte
is not necessary.

Always use two wrenches for the terminal
screws.

CZ-22

1. Terminal guard
2. Access doors
Battery cleaning and installation

2

WARNING!

Always wear eye protection when
around batteries.

WARNING!

Do not short battery terminals by
allowing a wrench or any other
object to contact both terminals at
the same time. Before connecting
battery, remove metal bracelets,
wristwatch bands, rings, etc.

Positive terminal must be connected
first to prevent sparks from
accidental grounding.

STANDARD

BATTERY

STATE

OF

CHARGE

APPROXIMATE BATTERY CHARGING TIME*

TO FULL CHARGE AT 80

O

F / 27

O

C

Maximum Rate at:

50 Amps

30 Amps

20 Amps

10 Amps

12.6V

100%

- FULL CHARGE -

12.4V

75%

20 min.

35 min.

48 min.

90 min.

12.2V

50%

45 min.

75 min.

95 min.

180 min.

12.0V

25%

65 min.

115 min.

145 min.

280 min.

11.8V

0%

85 min.

150 min.

195 min.

370 min.

*Charging time depends on battery capacity,

condition, age, temperature and efficiency of charger

Cleaning battery and terminals
Corrosion and dirt on the battery and terminals can
cause the battery to “leak” power.

Open the terminal access doors.

1.

Disconnect BlACK battery cable first, then

2.

the RED battery cable and remove the battery
from the machine.
Rinse the battery with plain water and dry.

3.

Clean terminals and battery cable ends with

4.

wire brush until shiny.
Coat terminals with grease or petroleum jelly

5.

Reinstall battery.

6.

Replacing battery

lift seat and rotate forward.

1.

Open terminal access doors

2.

Using two ½" wrenches disconnect BlACK

3.

battery cable then RED battery cable.
Using a

4.

7

/

16

wrench, remove the bolts on either

side of the terminal guard and lift off guard.
Carefully remove the battery from the mower.

5.

Install new battery with terminals in the same

6.

position as the old battery.
Reinstall battery terminal guard.

7.

first connect RED battery cable to positive (+)

8.

battery terminal with hex bolt and hex nut.
Connect BlACK grounding cable to negative

9.

(-) battery terminal with remaining hex bolt
and hex nut.
Close access doors.

10.

1

2

2

MaIntenanCe

36

This manual is related to the following products: