Specifications – Crompton Controls CIMR-VC4A0001BAA User Manual

Page 4

background image

4

YASKAWA V1000

Specifications

Voltage class

Single-phase 200 V

Inverter model CIMR-VCBA*

1

0001

0002

0003

0006

0010

0012

00018*

6

Inverter output

Motor output kW at normal duty*

2

0.18

0.37

0.75

1.1

2.2

3.0

Motor output kW at heavy duty *

2

0.1

0.18

0.55

0.75

1.5

2.2

4.0

Rated output current at normal duty [A]*

3

1.2

1.9

3.3

6

9.6

12

Rated output current at heavy duty [A]

0.8*

4

1.6*

4

3.0*

4

5.0*

4

8.0*

5

11.0*

5

17.5*

5

Overload

125% for 60 sec normal duty, 150 % for 60 sec
at heavy duty from inverter rated output current

Rated output power at normal duty [kVA]*

0.5

0.7

1.3

2.3

3.7

4.6

-

Rated output power at heavy duty [kVA]*

0.3

0.6

1.1

1.9

3.0

4.2

6.7

Max. output voltage

Three-phase 200 to 240 V (proportional to input voltage)

Max. output frequency

400 Hz

Inverter

input

Rated input voltage

Single-phase 200 to 240 V, -15% to +10%

Rated input frequency

50/60 Hz, ±5%

* based on input voltage 220 V

Voltage class

Three-phase 200 V

Inverter model CIMR-VC2A

0001

0002

0004

0006

0010

0012

0020

0030

0040

0056

0069

Inverter output

Motor output kW at normal duty*

2

0.18

0.37

0.75

1.1

2.2

3.0

5.5

7.5

11.0

15.0

18.5

Motor output kW at heavy duty*

2

0.1

0.2

0.4

0.75

1.5

2.2

4.0

5.5

7.5

11.0

15.0

Rated output current at normal duty [A]*

3

1.2

1.9

3.5

6.0

9.6

12.0

19.6

30.0

40.0

56.0

69.0

Rated output current at heavy duty [A]

0.8*

4

1.6*

4

3.0*

4

5.0*

4

8.0*

5

11.0*

5

17.5*

5

25.0*

5

33.0*

5

47.0*

5

60.0*

5

Overload

120% for 60 sec at normal duty, 150% for 60 sec at heavy duty from inverter rated output current

Rated output power at normal duty [kVA]*

0.5

0.7

1.3

2.3

3.7

4.6

7.5

11.4

15.2

21.3

26.3

Rated output power at heavy duty [kVA]*

0.3

0.6

1.1

1.9

3.0

4.2

6.7

9.5

12.6

17.9

22.9

Max. output voltage

Three-phase 200 to 240 V (proportional to input voltage)

Max. output frequency

400 Hz

Inverter

input

Rated input voltage

Three-phase 200 to 240 V, -15% to +10%

Rated input frequency

50/60 Hz, ±5%

* based on input voltage 220V

Voltage class

Three-phase 400 V

Inverter model CIMR-VC4A

0001

0002

0004

0005

0007

0009

0011

0018

0023

0031

0038

Inverter output

Motor output kW at normal duty*

2

0.37

0.75

1.5

2.2

3.0

4.0

5.5

7.5

11

15.0

18.5

Motor output kW at heavy duty*

2

0.18

0.37

0.75

1.5

2.2

3.0

4.0

5.5

7.5

11.0

15.0

Rated output current at normal duty [A]*

3

1.2

2.1

4.1

5.4

6.9

8.8

11.1

17.5

23.0

31.0

38.0

Rated output current at heavy duty [A]*

5

1.2

1.8

3.4

4.8

5.5

7.2

9.2

14.8

18.0

24.0

31.0

Overload

120% for 60 sec at normal duty, 150% for 60 sec at heavy duty from inverter rated output current

Rated output power at normal duty [kVA]*

0.9

1.6

3.1

4.1

5.3

6.7

8.5

13.3

17.5

23.6

29.0

Rated output power at heavy duty [kVA]*

0.9

1.4

2.6

3.7

4.2

5.5

7.0

11.3

13.7

18.3

23.6

Max. output voltage

Three-phase 380 to 480 V (proportional to input voltage)

Max. output frequency

400 Hz

Inverter

input

Rated input voltage

Three-phase 380 to 480 V, -15% to +10%

Rated input frequency

50/60 Hz, ±5%

* based on input voltage 400 V

*

1

Drives with a single-phase power supply input have three-phase output. Single-phase motors cannot be used.

*

2

The motor capacity (kW) refers to a YASKAWA 4-pole, 60 Hz, 200 V motor. The rated output current of the drive output amps should be equal to or greater than the motor rated current.

*

3

at 2 kHz carrier frequency without derating

*

4

at 10 kHz carrier frequency without derating

*

5

at 8 kHz carrier frequency without derating

*

6

only heavy duty available