Options – Crompton Controls CIMR-VC4A0001BAA User Manual
Page 10
10
YASKAWA V1000
Options
Name
Purpose
Model, Manufacturer
Input noise filter
Reduces noise from the line that enters into the drive input power system.
Should be installed as close as possible to the drive.
1-phase 200 V
Filter:
CIMR-VCBA0001
FS23638-10-07
CIMR-VCBA0002
FS23638-10-07
CIMR-VCBA0003
FS23638-10-07
CIMR-VCBA0006
FS23638-20-07
CIMR-VCBA0010
FS23638-20-07
CIMR-VCBA0012
FS23638-30-07
CIMR-VCBA0018
FS23638-40-07
3-phase 200 V
Filter:
CIMR-VC2A0001
FS23637-8-07
CIMR-VC2A0002
FS23637-8-07
CIMR-VC2A0004
FS23637-8-07
CIMR-VC2A0006
FS23637-8-07
CIMR-VC2A0010
FS23637-14-07
CIMR-VC2A0012
FS23637-14-07
CIMR-VC2A0020
FS23637-24-07
CIMR-VC2A0030
FS23637-52-07
CIMR-VC2A0040
FS23637-52-07
CIMR-VC2A0056
FS23637-68-07
CIMR-VC2A0069
FS23637-80-07
3-phase 400 V
Filter:
CIMR-VC4A0001
FS23639-5-07
CIMR-VC4A0002
FS23639-5-07
CIMR-VC4A0004
FS23639-5-07
CIMR-VC4A0005
FS23639-10-07
CIMR-VC4A0007
FS23639-10-07
CIMR-VC4A0009
FS23639-10-07
CIMR-VC4A0011
FS23639-15-07
CIMR-VC4A0018
FS23639-30-07
CIMR-VC4A0023
FS23639-30-07
CIMR-VC4A0031
FS23639-50-07
CIMR-VC4A0038
FS23639-50-07
Braking resistor
Used to shorten the deceleration time by dissipating regenerative energy through a resistor (3% ED).
ERF-150WJ series
24 V power supply
Provides power supply for the control circuit and option boards. Note: Parameter settings cannot be
changed when the drive is operating solely from this power supply.
PS-V10S
PS-V10M
USB copy unit
(RJ-45/USB compatible plug)
Adapter for connecting the drive to the USB port of a PC. (e.g. for Support Tool Drive Wizard Plus)
Can copy parameter settings to be later transferred to another drive.
JVOP-181
Support tools (DriveWizard Plus)
cable
Connects the drive to a PC for use with DriveWizard.
WV103
LCD operator
For easier operation when using the optional LCD operator. Allows for remote operation. Includes a
Copy function for saving drive settings.
JVOP-180
LCD operator extension cable
Cable for connecting the LCD operator.
WV001: 1 m
WV003: 3 m
Communication
interface
unit
MECHATROLINK-2
Allows control of the drive via a fieldbus network.
SI-T3/V
CC−link
SI-C3/V
DeviceNet
SI-N3/V
PROFIBUS−DP
SI-P3/V
CANopen
SI-S3/V
Momentary power loss recovery unit
Ensures continued drive operation for a power loss of up to 2 s.
P0010 type (200 V class)
P0020 type (400 V class)
Attachment for external heatsink
Mechanical kit to install the drive with the heatsink out of the cabinet.
Note: current derating must be considered when this installation method is used.
(Please contact your YASKAWA
representative)
Screw-type terminal board
Control terminal board with screw-type terminals.
Available soon
Plus operator mounting kit
For the use with holes through the panel.
100-039-992
For the use with panel mounted threaded studs.
100-039-993
Note: contact the manufacturer in question for availability and specifications of non-YASKAWA products.