4

Cast iron flue collar installation:

1. Peel off the tape from the back

of the gasket and attach the
gasket to the rope groove at
the back of the flue collar;

2. Mount flue collar on top of the

stove. Make sure that the
damper holes on each side of
the flue collar are parallel to the
back of the stove;

3. Fix the flue collar with the

hardware supplied;

4. Install the flue damper inside

the flue collar as illustrated.

Back air intake, ash dump cap,
and firebricks installation:

1. Slide the back air intake(A)

behind the bracket welded on
the back of the stove;

2. Install the bottom firebricks

first, then the side ones;

3. Install the back firebricks;
4. Insert the ash dump cap on

the bottom hole.

(A)