Maintenance – Casella CEL Multimet User Manual
Page 14

4.
MAINTENANCE AND SERVICE
4.1
Routine Maintenance
The Multimet is designed to provide many years of trouble free operation,
however, as with all mechanical systems, some regular maintenance and
inspection may be required.
Periodically check the system for the following:
Signs of physical damage Inspect the anemometer cups,
direction vane,
cabling,
connectors and mounting components
for signs of damage or deterioration.
Replace any damaged components as
necessary.
Ease of rotation
Ensure both the wind vane and cups are
free to rotate.
Excessive friction may indicate that
bearing replacement is required.
4.1.1 The Multimet
The display should require no maintenance other than periodic cleaning using
a soft cloth. DO NOT USE solvents or other cleaning products.
4.1.2 The Wind Speed and Direction Sensors
Cleaning the sensors and cross arm may be carried out using a soft damp
cloth. DO NOT USE solvents or other cleaning products.
Apart from cleaning, no other regular maintenance is required, as the
number of moving parts is so few and the bearings on the main spindle are
sealed against dust etc.
If the average wind speed is low and weather conditions moderate,
it is estimated that six years life can be expected from the bearings. With a
higher than average wind velocity and a bad exposure, for example near the
sea, then 4 to 5 years might be expected. At the end of this time it is
recommended that the bearings be replaced with new ones. Consult Casella
CEL Service Department.
4.2
Service
CASELLA CELs in house service department offers a comprehensive range
of repair and calibration services, designed to effect a fast and efficient
back-up for all our products. The Service Department is operated under the
scope of our BSI registration for products manufactured by us. We will
however, undertake the repair of other manufacturers equipment.
For further information please contact CASELLA CELs Service
Department at our Bedford premises. We will be happy to provide quotations
for individual repairs or provide annual maintenance under contract.
Maintenance
Page 14 of 16
MULTIMET Wind Speed and Direction System
& OnlinePro Software - Users Handbook