TROUBLESHOOTING

Continued

OBSERVED PROBLEM

Delayed ignition of burner

Burner backfiring during combustion

Yellow flame during burner combustion

Slight smoke or odor during initial operation

Appliance produces a whistling noise when
burner is lit

POSSIBLE CAUSE

1.

Manifold pressure is too low

2.

Burner orifice is clogged

1.

Burner orifice is clogged or damaged

2.

Inlet gas pressure is too low

3.

Burner damaged

4.

Gas regulator defective

1.

Not enough air

2.

Inlet gas pressure is too low

3.

Gas regulator defective

1.

Residues from manufacturing processes

1.

Turning control knob to HIGH position
when burner is cold

2.

Air in gas line

3.

Air passageways on appliance blocked

4.

Dirty or partially clogged burner orifice

REMEDY

1.

Contact local gas company

2.

Clean burner (see Cleaning and Main-
tenance
, page 11) or replace burner
orifice

1.

Clean burner (see Cleaning and Main-
tenance
, page 11) or replace burner
orifice

2.

Contact local gas company

3.

Replace burner

4.

Replace gas regulator

1.

Check burner for dirt and debris. If
found, clean burner (see Cleaning and
Maintenance
, page 11)

2.

Contact local gas company

3.

Replace gas regulator

1.

Problem will stop after a few hours of
operation

1.

Turn control knob to LOW position
and let warm up for a minute

2.

Operate burner until air is removed
from line. Have gas line checked by
local gas company

3.

Observe minimum installation clear-
ances (see Figure 4, page 6)

4.

Clean burner (see Cleaning and Main-
tenance
, page 11) or replace burner
orifice

Continued