beautypg.com

Owner’s manual, Inspecting burner, Cleaning and maintenance – Desa RN30E-CAN User Manual

Page 11

background image

11

105056

OWNER’S MANUAL

1/2 HEAT SHIELD
HEIGHT

INCORRECT FLAME PATTERN

AT HIGH POSITION

INSPECTING
BURNER

Check pilot flame pattern and burner flame
pattern often.

PILOT FLAME PATTERN

Figure 18 shows a correct pilot flame pat-
tern. Figure 19 shows an incorrect pilot
flame pattern. The incorrect pilot flame is
not touching the thermocouple. This will
cause the thermocouple to cool. When the
thermocouple cools, the appliance will shut
down.

If pilot flame pattern is incorrect, as shown
in Figure 19

• turn appliance off (see To Turn Off Gas

to Appliance, page 10)

• see Troubleshooting, pages 12 through 14

Figure 18 - Correct Pilot Flame Pattern

Figure 19 - Incorrect Pilot Flame Pattern

NOTICE: Do not mistake orange
flames with yellow tipping. Dirt
or other fine particles enter the
appliance and burn causing brief
patches of orange flame.

Thermocouple

Pilot Burner

Pilot Burner

Thermocouple

Figure 20 - Correct Burner Flame Pattern

Figure 21 - Incorrect Burner Flame Pattern

BURNER FLAME PATTERN

Figure 20 shows a correct burner flame
pattern. Figure 21 shows an incorrect burner
flame pattern. The incorrect burner flame
pattern shows yellow tipping of the flame. It
also shows the flame higher than 1/2 the
heat shield height.

If burner flame pattern is incorrect, as shown
in Figure 21

• turn appliance off (see To Turn Off Gas

to Appliance, page 10).

• see Troubleshooting, pages 12 through 14

WARNING: If yellow tipping

occurs, your CO2 generator could
produce increased levels of car-
bon monoxide. If burner flame
pattern shows yellow tipping, fol-
low instructions at bottom of this
page.

Yellow
Tipping

CLEANING AND
MAINTENANCE

WARNING: Turn off appliance

and let cool before cleaning.

CAUTION: You must keep con-

trol areas, burner, and circulating
air passageways of appliance
clean. Inspect these areas of ap-
pliance before each use. Have
CO2 generator inspected yearly
by a qualified service person. Ap-
pliance may need more frequent
cleaning due to excessive saw-
dust, cobwebs, etc.

ODS/PILOT AND BURNER

• Use a vacuum cleaner, pressurized air, or

small, soft bristled brush to clean.

CABINET

Air Passageways

• Use a vacuum cleaner or pressurized air

to clean.

Exterior

• Use a soft cloth dampened with a mild

soap and water mixture. Wipe the cabi-
net to remove dust.

CORRECT FLAME PATTERN

AT HIGH POSITION

1/2 HEAT SHIELD
HEIGHT

This manual is related to the following products: