BR 5232

Operating Instructions

fouled very quickly.

Sites with strong

Air currents from fans, open

air currents

windows, ventilation, etc.

Rooms with

Rooms below 0°C or higher

extreme

temperatures than 40°C

Rooms with high

The smoke detector’s measu-

incidence of

ing sensors can become fouled

insect pestsr

very quickly.

Smoking rooms

Cigar or pipe smoke, which
does come from fire, cannot be
differentiated from other fires
by a smoke detector.

In all rooms, there are certain points that must be
noted when mounting a smoke alarm.

Site

Description

Ceilingmount

Mount the smoke alarm on the
ceiling in a central position.
IMPORTANT: Areas in which
there is no air circulation
should be avoided, e.g. in the
vicinity of window sills, cur-
tains, furniture, etc. A minimum
distance of 30 cm should be
maintained. The smoke alarm
should be mounted at least

052109 Rauchmelder BR 5232 02.06.2009 19:19 Uhr Seite 19