3. Technical data
The CO-detector is calibrated so that it sounds in
response to the following CO-values, in compliance
with EN 50291-1:2010 + A1:2012.
CO concentration No alarm
Alarm
in the air
before
before
30 ppm
120 min.
-
50 ppm
60 min.
90 min.
100 ppm
10 min.
40 min.
300 ppm
-
3 min.
Protection class:
IP 20
Power :
9 Volt DC alkaline battery
(IEC 6LR61) or MN1604
Max. current:
< 40 mA (alarm)
Sound level of signal: 85 dB (1 m distance)
Battery life:
Min. 1 year
ATTENTION:
IMPORTANT!
THIS IS NOT A SMOKE ALARM! This CO-detector
was developed to detect carbon monoxide coming
from ANY combustion source. It was NOT
developed to detect smoke, fire or other gases.