2 accessories – DoorKing 1802 User Manual
Page 51

51
Surface Trim Ring
Use to recess surface mount 1803 or 1810 units into a wall or column.
P/N 1803-150.
Flush Kit
Use to install flush style 1803 or 1810 units into a wall or column. Kit
includes rough in back box and trim ring. P/N 1814-165 comes with
stainless steel trim ring. P/N 1814-166 comes with gold plated trim ring.
Flush Ring
Use to surface mount a flush style 1803 or 1810 unit. P/N 1814-152.
Stainless Steel Case
Replaces the black steel surface mount case on the 1803 and 1810 units
with a stainless steel case. P/N 1810-102.
Surge Suppressers
High voltage (120 V) suppresser: P/N 1878-076.
Phone line suppresser: P/N 1878-077.
Low voltage (28 V) suppresser: P/N 1878-078.
Mounting Post
Standard gooseneck mounting post: P/N 1200-045.
Standard gooseneck mounting post – long: P/N 1200-046
Heavy-duty gooseneck mounting post: P/N 1200-047.
Heavy-duty gooseneck mounting post – Long: P/N 1200-048.
Telephone Test Set
Includes clips, cord and carrying case. P/N 1800-050.
Battery
12 volt .8 amp hour gel cell provides stand by power during power
interruptions. P/N 1801-008.
SYMPTON POSSIBLE
SOLUTION(S)
Four-digit entry codes
will not work.
•
Forgetting to press # first.
•
Entry code is time zone restricted. Reprogram time zone or turn time zone off
(5.2.4).
•
Entry code attempted was a flash code that is no longer valid.
Five-digit entry codes
will not work.
•
Forgetting to press ## first.
•
Entry code is time zone restricted. Reprogram time zone or turn time zone off
(5.2.4).
Entry codes will not
activate relay 1.
•
Programmed entry codes are greater than the divide number. Reprogram
divide number or program entry codes less than the divide number.
Entry codes will not
activate relay 2.
•
Programmed entry codes are less than or equal to the divide number.
Reprogram divide number or program entry codes greater than the divide
number
System emits a beep
every 30 seconds.
•
Master code switch is in the ON position.
LCD is unreadable
(1802, 1803, 1810
units only).
•
Adjust contrast.
6.2 ACCESSORIES