2 single operation mode of skm 2-00 – AXING SKM 2-00 User Manual
Page 6

Installation and connection
Ausrufezeichen statt Hinweis
© AXING AG – state of the art: May 2012 – Reserving change in design and type
Page 6
3.2 Single operation mode of SKM 2-00
Before installing modules, the power supply must be switched off. Ground the module acc. to EN 50083-1,
EN 60728-11:2010 in order to avoid dangerous overvoltages (attention: risk of fire/death). Use the
grounding screw attached to the device (see ß in fig. 2 on page 4).
The modulation module has to be fastened to a wall or onto a flat surface. In single operation mode of the
SKM 2-00, the power supply is provided by the DC feeding socket (see 6 in fig. 2 on page 4). A separate
power supply unit SKZ 5-00 is required for it. More units are connected by means of the DC loop-through.
One DC connection cable SKZ 4-00 is included in the delivery of the SKP 2-00. Max. 4 pieces SKM 2-00
may be connected together in single operation mode.
Mount the power supply unit left of the SKM 2-00 module for better ventilation.
Fig. 4
Assembly and connection of a single twin module
Audio and video sources are connected to the cinch connectors at the front (see 8 in fig. 2 on page 4).
Inputs In single operation mode of the SKM 2-00, the outputs of the twin modules must be combined by
means of a splitter. The input splitters (SKV 2..8-00) in connection with F-double sockets (CFA 3-00) may
be used.