Installation and connection

Ausrufezeichen statt Hinweis

© AXING AG – state of the art: May 2012 – Reserving change in design and type

Page 5

3

Installation and connection

The SKM 2-00 can either be operated in a headend basic unit SKS x-xx or in stand alone mode.

3.1 Installation and connection in a headend base unit

If the SKM 2-00 should operate in a headend basic unit SKS x-xx, the twin module is plugged in the output
collection field 1 and fastened with screws. Each free slot may be used. The power supply of the module
is provided by the output collection field.

Before inserting or changing a module, pull the mains plug of the headends basic unit from the socket!
Ground the base plate in order to avoid dangerous overvoltages according to EN 50083-1, EN 60728-
11:2010 (attention: risk of fire/death)

For detailed information on the headend base unit, refer to whose operating instructions.

Fig. 3

Installation and connection a headend base unit

1

base plate without modules

base plate fully equipped