beautypg.com

Cleaning and maintenance, Inspecting burners – Desa VRL30PR User Manual

Page 26

background image

www.desatech.com

110021-01M

26

CLEANING AND

MAINTENANCE

WARNING: Turn off heater

and let cool before cleaning.

CAUTION: You must keep

control areas, burner and circu-

lating air passageways of heater

clean. Inspect these areas of

heater before each use. Have

heater inspected yearly by a quali-

fied service person. Heater may

need more frequent cleaning due

to excessive lint from carpeting,

bedding material, pet hair, etc.

WARNING: Failure to keep

the primary air opening(s) of

the burner(s) clean may result in

sooting and property damage.

BURNER INJECTOR HOLDERS AND
PILOT AIR INLET HOLES

The primary air inlet holes allow the proper

amount of air to mix with the gas. This provides

a clean burning flame. Keep these holes clear of

dust, dirt, lint and pet hair. Clean these air inlet

holes prior to each heating season. Blocked air

holes will create soot. We recommend that you

clean the unit every three months during operation

and have heater inspected yearly by a qualified

service person.
We also recommend that you keep the burner

tubes and pilot assembly clean and free of dust

and dirt. To clean these parts we recommend using

compressed air no greater than 30 PSI. Your local

computer store, hardware store or home center

may carry compressed air in a can. You can use a

vacuum cleaner in the blow position. If using com-

pressed air in a can, please follow the directions on

the can. If you don't follow directions on the can,

you could damage the pilot assembly.

BURNER FLAME PATTERNS

Figure 38 shows correct front and/or middle burner

flame patterns. Figure 39 shows incorrect front

and/or middle burner flame patterns. The incorrect

burner flame patterns show yellow tipping at top

of blue flame.

WARNING: If yellow tipping

occurs, your heater could pro-

duce increased levels of carbon

monoxide. If burner flame pat-

terns show yellow tipping, follow

instructions below. Yellow flame

on rear burner is normal.

NOTICE: Do not mistake orange

flames with yellow tipping. Dirt

or other fine particles are burned

by heater, causing brief patches

of orange flame.

If front and/or middle burner flame patterns are

incorrect, as shown in Figure 39
• turn heater off (see To Turn Off Gas to Appli-

ance, page 21 [Thermostat-Controlled Models]

or page 24 [Remote-Ready Models])

• see Troubleshooting, page 28

INSPECTING BURNERS

Continued

Figure 38 - Correct Burner Flame

Patterns

Figure 39 - Incorrect Burner Flame

Patterns

Yellow
Tipping At
Top of Blue
Flame

(CSG3924NT/PT, CSG3924NR/PR and

CSG3930NR/PR Models shown)

(CSG3924NT/PT, CSG3924NR/PR and

CSG3930NR/PR Models shown)

This manual is related to the following products: