OPERATING HEATER

Continued

Note:

Home owners generally prefer to op-

erate their heater with the chimney damper

closed. This will put all the heat into the room.

However, there may be times you will desire

the full flames of the HI heat setting but will

find the heat output excessive. You can open

the chimney damper (if you have one) fully or

partially to release some of the heat.

WARNING: Damper handle

will be hot if heater has been

running.

1. STOP! Read the safety information page 20.

2. Make sure equipment shutoff valve is

fully open.

3. Turn control knob clockwise

to the

OFF position.

4. Wait five (5) minutes to clear out any gas.

Then smell for gas, including near the floor.

If you smell gas, STOP! Follow “B” in the

safety information on page 20. If you donʼt

smell gas, go to the next step.

5. Turn control knob counterclockwise

to the PILOT position. Press in control

knob for five (5) seconds (see Figure 27).

Note:

You may be running this heater for

the first time after hooking up to gas sup-

ply. If so, the control knob may need to be

pressed in for 30 seconds or more. This will

allow air to bleed from the gas system.

6. With thermostat control knob pressed in,

press and release ignitor button. This will

light pilot. The pilot is attached to the front

burner. If needed, keep pressing ignitor

button until pilot lights.

Note:

If pilot does not stay lit, contact a

qualified service person or gas supplier for

repairs. Until repairs are made, light pilot

with match. To light pilot with match, see

Manual Lighting Procedure.

7. Keep control knob pressed in for 30 seconds

after lighting pilot. After 30 seconds, release

control knob.

• If control knob does not pop out when

released, contact a qualified service

person or gas supplier for repairs.

Note:

If pilot goes out, repeat steps 3

through 7. This heater has a safety interlock

system. Wait one minute for system to reset

before lighting pilot again.

8. Turn control knob counterclockwise

to desired heating level. The front burner

should light. Set control knob to any heat

level between HI and LO.

9. To light the rear yellow flame burner, push

in and turn rear burner control knob coun-

terclockwise

to the ON position.

CAUTION: Do not try to ad-

just heating levels by using the

equipment shutoff valve.

CAUTION: Do not try to adjust

heating level of rear burner. Rear

burner control knob should be in ON

or OFF positions only. Do not oper-

ate with rear burner control knob

between ON or OFF positions.

O

F

F

P

ILOT

LO

HI

A

U

T

O

O

F

F

O

N

O

N

Figure 27 - Control Knob(s) and Ignitor

Button Locations

Models: CSG3924NT, CSG3924PT,

VRL24NT, VRL24PT, VRL30NT and VRL30PT

Ignitor Button Control Knob

Rear Burner
Control Knob

Figure 28 - Pilot

(Propane/LP)

Ignitor Electrode

Figure 29 - Pilot

(Natural)

Ignitor Electrode

Pilot
Burner

Thermocouple

Thermocouple

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1. Turn control knob clockwise

to the

OFF position.

2. Turn rear burner control knob clockwise

to the OFF position.

Shutting Off Burners Only (pilot stays lit)

1. Turn control knob clockwise

to the

PILOT position.

2. Turn rear burner control knob clockwise

to the OFF position.