miniONYX Manual

switch on the side of the scale to the CAL position.

The scale will turn ON and go to zero.

2. Hold the MODE key until the display shows “CAL”,

then release.

3. Tap the MODE key again. The display will flash

“CAL” followed by “500.0g”.

4. Place a 500g calibration weight on the center of the

platform. The display will flash “PASS”. Calibration

is complete!

5. You can now use the lock switch on the side to re-

turn the scale to normal (unlocked) weighing mode.

X. Troubleshooting

Problem: Scale will not turn on

Solution: Check the batteries

Problem: Displayed weight fluctuates randomly

Solution: Make sure your workspace is stable and

free of any air currents or vibration

Problem: Displayed weight is inaccurate

Solution: Perform a calibration adjustment

XI. Error Codes

1. OUTZ - Zero range has shifted. Perform calibration

adjustment. If the problem persists, the load cell may

be permanently damaged due to overloading.

2. 88888 - Maximum capacity exceeded. Remove the

extra weight to avoid damaging the load cell.

3. L - Batteries are low. Replace the batteries.