4. ORDERING DETAILS
TYPE
DESCRIPTION
Product
LPI-T
Loop Power Indicator
Transmitter
Output
D
4~20 mA dc
Alarm
N
No Alarm
1
1-Alarm
2
2-Alarm
Accessories
N
None
Y
Screw and Packing Gasket
Example: LPI-T > D > N > N
5. CONNECTIONS
To connect the LPI-T simply plug into an existing transmitter by means of a
special adaptor for the DIN43650 plug.
Supply voltage: Device takes power directly from measuring current. Please allow for
an additional loop voltage drop of 3 Volts.
Caution: Wrong electrical connection may lead to the destruction of the device.
Mind the maximum input current rating of 40 mA under any circumstances!
ELECTRICAL CONNECTIONS
2-wire
system
Supply +
Red
Supply -
Black