Installation Guide

* Wiring configuration and connection to motorized Screen and Video Projector.

ABtUS AVS-SSR8/1

Caution with main supply and live wires. Install with qualified

technician or trained personnel only.

ABtUS AVS-SSR8/1

Warning

Works on momentary contact closure

(dry contact, normally open, voltage free) only.

Contact closure must set close for 1.5 seconds.

(Warranty void if damaged is caused by inappropriate use.)

MOTORIZED

PROJECTION

SCREEN

PROJECTOR

DRY CONTACT

CONTROL

IR CONTROL

RS-232 CONTROL

AC-IN

220 to 240VAC

RS-232 PROGRAMMING

Example:
Projector communication parameter are as followed :
Baud rate : 19200bps, Data length : 8bits, Parity : No Parity, Stop bit : One bits.

**As the SCR8V2 could ONLY support “one stop bit” hence there NO requirement for “STOP” bit setting

Transmitted Code : 53 45 54 52 02 42 41 55 01 00
Returned Code

: 52 54 55 4E 02 42 41 55 01 00

3. Setting the “Layering Function” :

Header code

: 53H 45H 54H 52H

Data code length : 02H

Command ID

: 53H 50H 46H

Data code

: XXH YYH

XXH =>Function as stated below:

(1). 00H => STOP KEY function, “Stop” function for screen control ONLY.
(2). 01H => RS232/IR Projector command code Auto repeater function for Power ON and

Power OFF. WHEN Enabled: ONLY “Power ON” a second set of command RS-232

command will sent automatically. **Some projector would require a second

“Power ON”code to turn the Power ON. And for “Power OFF” a second set of IR

command will be send as most projector would require a second set of “Power OFF”

to confirm and OFF command.

(3). 02H => Setting the First / Second layer

WHEN Enable: The switcher will operate both screen and projector in just

“one press”of a button. Else it would be under normal condition where by the

“first layer, one press” will ONLY operate the screen while the “second layer,

press and hold for 2 sec” this will then operate both the screen and Projector.

YYH => Enable and disable function.

00H => To Enable

01H => To Disable
Example:

To enable the STOP function:

Transmitted Code : 53 45 54 520253 50 460000

Returned Code

: 52 54 55 4E0253 50 460000

To enable the Auto repeater function:

Transmitted Code : 53 45 54 520253 50 460100

Returned Code

: 52 54 55 4E0253 50 460100

To enable the First / Second layer:

Transmitted Code : 53 45 54 520253 50 4602 00

Returned Code

: 52 54 55 4E0253 50 460200