CHECKING GAS CONNECTIONS

WARNING: Test all gas pip-

ing and connections, internal
and external to unit, for leaks
after installing or servicing. Cor-
rect all leaks at once.

WARNING: Never use an

open flame to check for a leak.
Apply a noncorrosive leak de-
tection fluid to all joints. Bubbles
forming show a leak. Correct all
leaks at once.

CAUTION: For propane/LP

gas, make sure external regula-
tor has been installed between
propane/LP supply and heater.
See guidelines under Connect-
ing to Gas Supply

, page 12.

PRESSURE TESTING GAS SUPPLY
PIPING SYSTEM

Test Pressures In Excess Of 1/2 PSIG
(3.5 kPa)
1. Disconnect appliance with its appliance main

gas valve (control valve) and equipment
shutoff valve from gas supply piping system.
Pressures in excess of 1/2 psig will damage
heater regulator.

2. Cap off open end of gas pipe where equip-

ment shutoff valve was connected.

3. Pressurize supply piping system by either

opening propane/LP supply tank valve for
propane/LP gas or opening main gas valve lo-
cated on or near gas meter for natural gas, or
using compressed air.

4. Check all joints of gas supply piping system.

Apply a noncorrosive leak detection fluid to
all joints. Bubbles forming show a leak.

5. Correct all leaks at once.
6. Reconnect heater and equipment shutoff

valve to gas supply. Check reconnected fit-
tings for leaks.

Tee Joint

Reducer
Bushing to
1/8" NPT

1/8" NPT
Plug Tap

Test Gauge

Connection*

3/8" NPT
Pipe Nipple

Heater
Cabinet

Equipment
Shutoff
Valve *

3" Min.

Natural Gas
From Gas Meter (4" W.C.
to 10.5" W.C. Pressure)
Propane/LP
From External Regulator
(11" W.C. to 14" W.C.
Pressure)

Ground Joint
Union

WARNING: Use pipe joint

sealant that is resistant to liquid
petroleum (LP) gas.

Install sediment trap in supply line as shown in
Figure 15. Locate sediment trap where it is within
reach for cleaning. Locate sediment trap where
trapped matter is not likely to freeze. A sediment
trap traps moisture and contaminants. This keeps
them from going into heater controls. If sediment
trap is not installed or is installed wrong, heater
may not run properly.
IMPORTANT:

Hold the pressure regulator with

wrench when connecting it to gas piping and/or
fittings. Do not over tighten pipe connection to
regulator. The regulator body could be damaged.

Tee Joint

Pipe
Nipple

Cap

Sediment Trap

INSTALLATION

Continued

Figure 15 - Gas Connection

Pressure
Regulator

* A CSA design-certified equipment shutoff valve
with 1/8" NPT tap is an acceptable alternative to
test gauge connection. Purchase the optional CSA
design-certified equipment shutoff valve from
your dealer. See Accessories, page 30.