No heat or heat too low

Spa Lights won't come on

Pump will not prime

Jets won't come on

Probable Cause #1

Action

Dirty Filter

Clean Filter / Pull Filter and try running without filter

Probable Cause #2

Action

Probable Cause #3

Action

Breaker at house off.

Reset breaker at house. Breaker can appear to

be on and one pole can be off. Turn breaker OFF

then ON twice.

Pump not primed.

Refer to the section of this manual on pump

priming

Probable Cause #4

Action

Improper line voltage.

Have a Licensed Electrician check the line voltage.

Probable Cause #1

Action

Light bulb burnt out.

Replace bulb. (non-warranty)

Probable Cause #2

Action

Dirty connection

Check to see if there is anything covering the con-

nection on the housing that holds the light bulb.

Probable Cause #1

Action

No water in pump

Make sure water level in spa is correct. Bleed top

air bleed on face of pump till water flows out.

Probable Cause #1

Action

Pump not primed.

Refer to the section of this manual on pump priming.

Probable Cause #2

Action

Gates Valves closed.

Check to see if gate valves are in the correct position.

Check to see that pump is purged in.

Probable Cause #2

Action

Closed gate valves or blocked lines.

Open all gate valves. Check suction for blockage

Probable Cause #4

Action

Air lock

Bleed off air at air relief valve on pump.

Probable Cause #3

Action

Pump surges, jets lose power, then comes back,

then loses power again etc.

Check union on front or nose of pump to ensure

tightness. Check drain plugs to ensure tightness.

T r o u b l e S h o o t i n g G u i d e