No heat or heat too low
Spa Lights won't come on
Pump will not prime
Jets won't come on
Probable Cause #1
Action
Dirty Filter
Clean Filter / Pull Filter and try running without filter
Probable Cause #2
Action
Probable Cause #3
Action
Breaker at house off.
Reset breaker at house. Breaker can appear to
be on and one pole can be off. Turn breaker OFF
then ON twice.
Pump not primed.
Refer to the section of this manual on pump
priming
Probable Cause #4
Action
Improper line voltage.
Have a Licensed Electrician check the line voltage.
Probable Cause #1
Action
Light bulb burnt out.
Replace bulb. (non-warranty)
Probable Cause #2
Action
Dirty connection
Check to see if there is anything covering the con-
nection on the housing that holds the light bulb.
Probable Cause #1
Action
No water in pump
Make sure water level in spa is correct. Bleed top
air bleed on face of pump till water flows out.
Probable Cause #1
Action
Pump not primed.
Refer to the section of this manual on pump priming.
Probable Cause #2
Action
Gates Valves closed.
Check to see if gate valves are in the correct position.
Check to see that pump is purged in.
Probable Cause #2
Action
Closed gate valves or blocked lines.
Open all gate valves. Check suction for blockage
Probable Cause #4
Action
Air lock
Bleed off air at air relief valve on pump.
Probable Cause #3
Action
Pump surges, jets lose power, then comes back,
then loses power again etc.
Check union on front or nose of pump to ensure
tightness. Check drain plugs to ensure tightness.
T r o u b l e S h o o t i n g G u i d e
29