Your spa will automatically filter itself twice each day. The first filter

cycle will begin 1 minute after the spa is energized. The second filter cycle

will begin 12 hours after the start of the first filter cycle. Filter duration

is programmable at the topside panel for 0, 1, 2, 3, 4 or 12 hours. The

default filter time is 2 hours. To program, press the or pad,

then the pad. Continue to press the or pad to select

the filter duration. Press the pad again to exit programming. The

low speed of pump 1 constantly runs during the filter times (unless the

high speed is on). The ozone generator (if installed) will run 24 hours

a day.

OH

FL

S

n

Overheat Protection (Spa is deactivated)

If the high limit sensor detects 40 F at the heater, then the high speed

of pump 1 and pump 2 (if installed) automatically activates to provide

freeze protection. The equipment stays on until the sensor detects

45 F at the heater. Freeze protection is activated regardless of the spa's

status. In colder climates, an optional additional freeze sensor may be

added to protect against freeze conditions. See your dealer for details.

DO NOT ENTER THE WATER. If the spa water has reached 112 F, remove

the spa cover to cool the water. Overheating may occur if the filter cycle

is set too long. At 110 F, the spa should reset itself. If the high limit sensor

detects 118 F at the heater, the spa will shut down. When the heater

cools to 110 F, press any button to reset the spa. If the spa will not

reset, then shut off power to the spa and call your dealer or service

organization.

Flow Switch Detection

The high-limit sensor or water temperature sensor is not working. Call

your dealer or service organization.

Sensor (Spa is deactivated)

WARNING! SHOCK HAZARD! No User Serviceable Parts.

Do not attempt service of this control. Contact you dealer or service

organization for assistance. Follow all owner's manual power connection

instructions. Installation must be performed by a licensed electrician and

all grounding connections must be properly installed.

Preset Filter Cycles

Freeze Protection

Diagnostic Messages

To p S i d e C o n t r o l I n s t r u c t i o n s

Flashing alternately with temperature. The filter may need cleaning.

The water level is too low. Be sure flow valves are open.

FL

(NOT

FLASHING) a pressure switch has malfunctioned. Contact your dealer

or service organization.

13