beautypg.com

Owner’s manual, Inspecting burner, Cleaning and maintenance – Desa CGP6L User Manual

Page 11

background image

11

103547

OWNER’S MANUAL

BURNER FLAME PATTERN

Figure 20 shows a correct burner flame
pattern. Figure 21 shows an incorrect burner
flame pattern. The incorrect burner flame
pattern shows yellow tipping of the flame. It
also shows the flame higher than 1/2 the
glass panel height.

NOTICE: Do not mistake orange
flames with yellow tipping. Dust
or other fine particles enter the
heater and burn causing brief
patches of orange flame.

WARNING: If yellow tipping

occurs, your heater could pro-
duce increased levels of carbon
monoxide. If burner flame pat-
tern shows yellow tipping, follow
instructions at bottom of this
page.

INSPECTING
BURNER

Continued

CORRECT FLAME PATTERN

AT HIGH POSITION

1/2 GLASS HEIGHT

If burner flame pattern is incorrect, as shown in Figure 21

• turn heater off (see To Turn Off Gas to Appliance, page 10)

• see Troubleshooting, pages 12 through 14

Figure 20 - Correct Burner Flame Pattern

(Model CGP6L will be lower due to lower input rating)

1/2 GLASS HEIGHT

INCORRECT FLAME PATTERN

AT HIGH POSITION

Yellow
Tipping

Figure 21 - Incorrect Burner Flame Pattern

(Model
CGP10L)

CLEANING AND
MAINTENANCE

ODS/PILOT AND BURNER
ORIFICE

• Use a vacuum cleaner, pressurized air,

or small, soft bristled brush to clean.

CABINET

Air Passageways

• Use a vacuum cleaner or pressurized air

to clean.

Exterior

• Use a soft cloth dampened with a mild

soap and water mixture. Wipe the cabi-
net to remove dust.

WARNING: Turn off heater

and let cool before cleaning.

CAUTION: You must keep

control areas, burner, and circu-
lating air passageways of heater
clean. Inspect these areas of
heater before each use. Have
heater inspected yearly by a quali-
fied service person. Heater may
need more frequent cleaning due
to excessive lint from carpeting,
bedding material, etc.