SAFETY FEATURES

The pressure washer is equipped with a stop device which will sense when the trigger on the gun
is released. It will open the power circuit to the motor and cause the pressure washer to stop.

The pressure washer is also equipped with a main power ON/OFF switch
located on the unit. It should always be moved to the off position when the

pressure washer is not being used to prevent possible injury or damage.

MOTOR OVERLOAD
The electric motor in this pressure washer is equipped with an overload protection device which
will automatically shut off the motor in the event the motor draws excessive current or overheats.
The device will automatically reset itself and resume normal operation after a short period of time.

GROUND-FAULT CIRCUIT-INTERRUPTER PROTECTION
This pressure washer is provided with a ground-fault circuit-
interrupter (GFCI) built into the plug of the power supply cord.
This device provides additional protection from the risk of
electric shock. Should replacement of the plug or cord
become necessary, use only identical replacement parts that
include GFCI protection.

EXTENSION CORDS

extension cords are not recommended
unless they are plugged into a ground-

fault circuit-interrupter found in circuit boxes or protected
receptacles.
Use only 3-wire extension cords that have 3-prong grounding-type plugs and 3-pole cord
connectors that accept the plug from the product.
Use only extension cords that are intended for outdoor use. These extension cords are identified
by a marking “Acceptable for use with outdoor appliances; store indoors while not in use”.
Use only extension cords having an electrical rating higher than the rating of the product.
Do not use damaged extension cords. Examine extension cord before using and replace if
damaged.
Do not abuse extension cord and do not yank on any cord to disconnect. Keep cord away from
heat and sharp edges. Always disconnect the extension cord from the receptacle before
disconnecting the product from the extension cord.

When using an extension cord, observe the specification below:

Cable Length

Wire Gauge

Up to 50 ft.

14 AWG

50 to 100 ft.

12 AWG

To reduce the risk of electrocution, keep all connections dry and off the