0 troubleshooting – DeVillbiss Air Power Company Water Driver WD1600E User Manual
Page 16
16- ENG
D28921
7.0 TROUBLESHOOTING
Proceed as follows:
l Disconnect unit from electrical outlet.
l Remove cover (Fig. A)
l Insert a suitable hexagon socket wrench (size 4 mm.) through the middle opening in the fan
cover and into the hexagon socket in the motor shaft.
l Turn the motor shaft clockwise by hand several times (Fig. B)
l Remove hexagon socket wrench
l Install cover
l Plug unit into electrical outlet
l Switch on machine with spray gun open.
Fig. A
Fig. b
Motor will not start or
stops while operating
GFCI tripped or not reset
Turn off unit. Press GFCI reset
button firmly after it has been
connected to the electrical supply
Circuit breaker tripped or fuse
blown in circuit fuse box
Disconnect all other loads on the
same circuit and reset circuit breaker
or replace fuse
Loose or disconnected plug
Reconnect plug
Tripped pressure washer
circuit breaker
Allow to cool and restart unit
Circuit breaker trips or
fuse blown in fuse box
Circuit Overload
Check that the circuit is rated 15
amps or greater. Disconnect all
loads on the circuit
Extension cord too long or
wire size too small
Use proper extension cord as
recommended in Operator's Manual
Nozzle partially blocked
Clean nozzle as instructed in
Section 5.2
Excessive pressure
Reduce pressure by using pressure
adjustment knob
GFCI trips repeatedly
Incorrect voltage
See Section 3.3
Internal short
Call Customer Service Department
PROBLEM
POSSIBLE CAUSE
CORRECTION