beautypg.com

0 troubleshooting – DeVillbiss Air Power Company Water Driver WD1600E User Manual

Page 16

background image

16- ENG

D28921

7.0 TROUBLESHOOTING

Proceed as follows:
l Disconnect unit from electrical outlet.
l Remove cover (Fig. A)
l Insert a suitable hexagon socket wrench (size 4 mm.) through the middle opening in the fan

cover and into the hexagon socket in the motor shaft.

l Turn the motor shaft clockwise by hand several times (Fig. B)
l Remove hexagon socket wrench
l Install cover
l Plug unit into electrical outlet
l Switch on machine with spray gun open.

Fig. A

Fig. b

Motor will not start or
stops while operating

GFCI tripped or not reset

Turn off unit. Press GFCI reset
button firmly after it has been
connected to the electrical supply

Circuit breaker tripped or fuse
blown in circuit fuse box

Disconnect all other loads on the
same circuit and reset circuit breaker
or replace fuse

Loose or disconnected plug

Reconnect plug

Tripped pressure washer
circuit breaker

Allow to cool and restart unit

Circuit breaker trips or
fuse blown in fuse box

Circuit Overload

Check that the circuit is rated 15
amps or greater. Disconnect all
loads on the circuit

Extension cord too long or
wire size too small

Use proper extension cord as
recommended in Operator's Manual

Nozzle partially blocked

Clean nozzle as instructed in
Section 5.2

Excessive pressure

Reduce pressure by using pressure
adjustment knob

GFCI trips repeatedly

Incorrect voltage

See Section 3.3

Internal short

Call Customer Service Department

PROBLEM

POSSIBLE CAUSE

CORRECTION