Nexen XTB Cooling Enhancement 835175 User Manual
Page 4

1
FORM NO. L-20232-A-0601
INTRODUCTION
Read this manual carefully, making full use of its explanations and instructions. The “Know How” of safe, continuous,
trouble-free operation depends on the degree of your understanding of the system and your willingness to keep all
components in proper operating condition. Pay particular attention to all NOTES, CAUTIONS, and WARNINGS to avoid
the risk of personal injury or property damage. It is important to understand that these NOTES, CAUTIONS, and
WARNINGS are not exhaustive. Nexen cannot possibly know or evaluate all conceivable methods in which service may
be performed, or the possible hazardous consequences of each method. Accordingly, anyone who uses a procedure
that is not recommended by Nexen must first satisfy themselves that neither their safety or the safety of the product will
be jeopardized by the service method selected.
INSTALLATION
1.
Using 10-24 x75 Locking Screws (Item 7) secure
Blower (Item 1) to the Blower Adaptor (Item 4) (See
Fig. 1).
2.
Remove Guard from XTB Brake (See Fig. 1).
3.
Align Blower and Blower Adaptor with the opening in
front of the XTB Guard (See Fig. 1).
4.
Using 10-24 x 38 Socket Head Cap Screws (Item 6),
Washers (Item 5), and Mounting Plate (Item 3)
secure Blower and Blower Adaptor to the “XTB”
Guard (See Fig. 1).
NOTE: The Mounting Plate (Item 3) has two
different bolt patterns. Select the correct
bolt pattern for the XTB Brake that the
Cooling Enhancement is being mounted on
(See Fig. 2).
5.
Install Guard with XTB Cooling Enhancement onto
XTB Brake.
6.
Connect the two Electrical Leads for the Blower to a
110 volt, 60 Hz Power Supply.
The Blower Motor must be grounded.
FIGURE 1
6
5
3
4
1
7
Electrical
Leads
XTB
Guard
XTB 10
XTB 12
XTB 14
XTB 18
FIGURE 2
MAINTENANCE
1.
Lubricate the Blower Motor every six months. Two
lubrication access holes are located on the Blower
Motor.
2.
Check the Mounting Screws every six months,
making sure that they are tightened securely.