5

FORM NO. L-20313-E-0612

PNEUMATIC CONNECTIONS

NOTE: Nexen's EN50 requires clean, pressure

regulated air for maximum performance and long

life. Your Nexen Distributor carries filters and

regulators specifically designed to operate with

Nexen products.

A Pre-filter (rated at 5.0 micron or less) removes

large particles from the air supply. The Final Filter

(rated at 0.1 micron or less) is used to filter the air

before it enters the Nexen EN50.

Clean all pipelines to remove dirt and scale before

installation. If you use a pipe compound when

installing the pipe or tube fittings into the Nexen

EN50, use a Teflon dope as a sealant.

1. Apply a minimum amount of pipe sealant

compound to the male threads of the fitting only;

then, start at the third thread back and work away

from the end of the fitting to avoid the possibility of

contaminating the Nexen EN50.

NOTE: The inlet and outlet ports are labeled on the

side of the EN50. User connections should be made

to the inlet and outlet ports located in the bottom of

the valve body only (See Figure 2).

2. Install the Nexen EN50 in the air line and securely

tighten the connections.

3. Install the plugs supplied with the Nexen EN50 in

all unused ports.

OUT

ZERO

IN

SPAN

OUT

IN

FIGURE 2

Make air connections

to bottom block only.

ELECTRICAL CONNECTIONS

Refer to Figure 3 for electrical connections.

Figure 3