beautypg.com

Introduction, Installation – Nexen TB800 911542 User Manual

Page 5

background image

(1)

FORM NO. L-21080-A-0700

INTRODUCTION

FIGURE 3

The TB800 Booster Amplifier amplifies control signals from Nexen tension controls into the electric signals needed for
operating an electro-magnetic brake or clutch.

• Variable output signal varies directly with input signal
• Constant current output circuit
• External potentiometer or signal input operation
• Adjustable output range

Functions:

INSTALLATION

1.

Install the TB800 Booster Amplifier in a shock and
vibration free area that has an ambient temperature
of less than 120°F [50°C] and more than 32°F [0°C].

2.

Mount the TB800 securely using 4 M5 screws. See
Figure 1 for mounting hole dimensions.

3.

Use 18 AWG [0.9 mm

2

] wire rated for 600V when

connecting the output to a brake or clutch.

4.

Set the AC Select connector to the supply voltage
used (100, 110, 200 or 220 VAC). (See Figure 4)

5.

Connect the Brake/Clutch, AC Power Supply and the
Control Signal to the TB800.

NOTE:

Refer to Figure 2 if amplifier is operated with an

external control signal (0-10 VDC)*. Refer to Figure 3 if
amplifier is operated manually with an external
potentiometer.

FIGURE 2

FIGURE 1

1

* For voltage ranges other than 0-10 VDC, see Compensating
Input Voltage in OPERATION section.

6.7 in [170 mm]

6.6 in [16

8 mm]

+

+

+

+

.23 in [5.8 mm] Diameter 4x

1

2

5

6

8

9

10

+

+

External Control Signal

BRAKE/CLUTCH

CONTROL SIGNAL

AC POWER SUPPLY

AC100, 110, 200, OR 220v, 50/60 Hz

1

2

4

5

8

9

10

+

Manual Control

BRAKE/CLUTCH

POTENTIOMETER (2k )

AC POWER SUPPLY

AC100, 110, 200, OR 220v, 50/60 Hz

6

1

2

3