INTRODUCTION
FIGURE 3
The TB800 Booster Amplifier amplifies control signals from Nexen tension controls into the electric signals needed for
operating an electro-magnetic brake or clutch.
• Variable output signal varies directly with input signal
• Constant current output circuit
• External potentiometer or signal input operation
• Adjustable output range
Functions:
INSTALLATION
1.
Install the TB800 Booster Amplifier in a shock and
vibration free area that has an ambient temperature
of less than 120°F [50°C] and more than 32°F [0°C].
2.
Mount the TB800 securely using 4 M5 screws. See
Figure 1 for mounting hole dimensions.
3.
Use 18 AWG [0.9 mm
2
] wire rated for 600V when
connecting the output to a brake or clutch.
4.
Set the AC Select connector to the supply voltage
used (100, 110, 200 or 220 VAC). (See Figure 4)
5.
Connect the Brake/Clutch, AC Power Supply and the
Control Signal to the TB800.
NOTE:
Refer to Figure 2 if amplifier is operated with an
external control signal (0-10 VDC)*. Refer to Figure 3 if
amplifier is operated manually with an external
potentiometer.
FIGURE 2
FIGURE 1
1
* For voltage ranges other than 0-10 VDC, see Compensating
Input Voltage in OPERATION section.
6.7 in [170 mm]
6.6 in [16
8 mm]
+
+
+
+
.23 in [5.8 mm] Diameter 4x
1
2
5
6
8
9
10
+
+
External Control Signal
BRAKE/CLUTCH
CONTROL SIGNAL
AC POWER SUPPLY
AC100, 110, 200, OR 220v, 50/60 Hz
1
2
4
5
8
9
10
+
Manual Control
BRAKE/CLUTCH
POTENTIOMETER (2k )
AC POWER SUPPLY
AC100, 110, 200, OR 220v, 50/60 Hz
6
1
2
3