Nexen RSD200 964531 User Manual
Page 10

FORM NO. L-21161-E-0108
10
Figure
Table 1
Designation
Color
Function
I1
Green
"ON when +5 VDC is present
I2
Green
"ON" when +12 VDC is present
I3
Red
"ON" when increasing air pressure
I4
Red
"ON" when decreasing air pressure
I5
Yellow
"ON" when voltage is applied to boost Input
I6
Yellow
"ON" when voltage is applied to Machine State Input
I7
Yellow
"ON" when in manual control
Auxiliary
RS232 Port
Rotary
Switch
I6
I5
P3
P4
P5
Jumper
Indicator
12V
W4
10V
12V
W3
10V
R35
R38
R37
U4
DIG IN 2
W6
TX
DIG IN 1
W5
RX
I4
I3
I2
I7
I1
1
W2
2
U13
REV
W1
NORM
I OUT
W7
V OUT
Not Used
Optional
Pressure
Sensor
Connection
Red
black
White
J
uMPeR
anD
S
witCh
S
ettingS
: (R
efeR
to
f
iguRe
7.)
NORM, if controller action is backwards, then select REV
Position 1, enables RSD Communications for remote setup
10 V or 12 V, depends on maximum output voltage of sensor, use
10 V for Nexen’s DPS 30A or DPS 60A sensor, and 12V for mechanical potentiometer
10 V
Dig. In 1, if using this input for Start/Stopped Signal
Rx, if using this input for RS232 communication
Dig. In 2, if using this input for Splice Signal
Tx, if using this input for RS232 communication
V Out, for 0 – 10 VDC analog output
I Out, for 4 – 20 mA analog output
Refer to Table 2
Jumper W1
Jumper W2
Jumper W3
Jumper W4
Jumper W5
Jumper W6
Jumper W7
Rotary Switch